When you switch to a unified log for all servers, you will not be able to access data about previous local events recorded in Events section. These events are saved in the Windows CertiFlow/Operational log on each CertiFlow server.
To record events from all CertiFlow servers in one log, configure each server to work with a unified event log.
Follow these steps to configure CertiFlow server to work with unified event log:
Log in to the CertiFlow server as a local administrator.
Run the Axidian CertiFlow Configuration Wizard (Start – All Programs – Axidian).
Go to Event Log section.
Click Enable Axidian CertiFlow Event Log Proxy if the Event Log Proxy application is used for the unified event log, and specify:
Event Log Proxy URL– URL of the remote log service.
https://<Workstation FQDN>/eventlogroxy
Service account for event log proxy– username for connecting to the eventlogproxy service (from the <authorization> section of the Web.config file of the eventlogproxy application).
Select Use Axidian Log Server if the unified event log is configured via the Axidian Log Server application and specify:
Axidian Log ServerURL – URL of the remote log service.
https://<Workstation FQDN>/ls/api
4. Go to the Confirmation section and click Apply. 5. Configure to work with a unified event log by repeating steps 2-4 on each CertiFlow server. 6. Go to the Axidian CertiFlow Management Console in a browser and search in the Events section. Expected Result: no errors.
A search in the Events may not produce results if the log on the remote server does not contain any events. Perform on the CertiFlow server configured to work with a unified event log any action the result of which is written to the Events (disabling the smart card, adding or changing comments, etc.) and repeat the search for events.