You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 5 Next »

Smart card usage control is carried out with Indeed Certificate Manager client Agent installed onto user workstations. The Control section defines the actions and message texts (optional) that are executed in case of violating the device usage rules. E.g. when a user connects his or her smart card to workstation of another user. The description of section parameters is given in Table 6.

Table 6 – Smart card usage settings.

OptionDescription

Message to the user when the bound device and agent do not match

The message displayed to the user by Indeed CM Agent upon connecting a smart card to workstation disallowed by administrator.

If the value is not set, the message is not is displayed.

The action to be taken when the bound device and agent do not match

The action performed by Indeed CM Agent upon connection of a smart card to workstation disallowed by administrator. Possible values:

  • Write event
  • Lock user session, write event
  • Lock card, write event
  • Lock user session and card, write event
Enable user card binding

If enabled, Indeed CM Agent checks whether the smart card belongs to the logged on user.

Message to the user when the bound device and user do not match

The message displayed to the user by Indeed CM Agent upon connection of a smart card to workstation with another user session active.

If the value is not set, the message is not is displayed.

The action to be taken when the bound device and user do not match

The action performed by Indeed CM Agent upon connection of a smart card to workstation with another user session active. Possible values:

  • Write event
  • Lock user session, write event
  • Lock card, write event
  • Lock user session and card, write event

Timeout before locking the user session (sec.)

Period of time until user session is locked if this action is selected to be executed by Indeed CM Agent upon smart card usage rule violation. Possible interval is from 0 to 5 seconds.

  • No labels