Versions Compared
Key
- This line was added.
- This line was removed.
- Formatting was changed.
This section defines smart card issuance and initialization parameters. The description of section parameters is given in the Table 5.
Table 5 – Smart card issuance parameters.
Option | Description | ||
---|---|---|---|
Maximum number of cards per user | The number that limits card quantity per user. Default value is 1. | ||
Initialize card | If enabled, the card is initialized before issuance. Initialization deletes all the data stored on the card. | ||
Set random user PIN | If enabled, a random user PIN code will be set while issuing a card.
The randomly generated PIN code conforms to the following rules:
The randomly generated PIN code can be communicated to the employee who performs card issuance. If the Issuance and Card initialization sections contain different values of user PIN code length, then the greater value is used while issuing the card. | ||
User PIN must be changed on first logon | If enabled, the user must change his/her card PIN code upon first login to a workstation. The option is supported by Gemalto (eToken) smart cards only. This option and Set random user PIN and Lock card are mutually exclusive. | ||
Lock card | If enabled, the card is blocked after issuance. Therefore, the user must first unlock it by any of available methods (online or offline) and define a new PIN code. | ||
Generate card name automatically | If enabled, one of the following user property values can be used as card name:
Selected value would be automatically placed to the card name field in the issuance window. If Allow editing card name option is enabled, the name of the card can be changed before issuance by the user or by employee who performs card issuance. |